LMA-GDF-20/400-HP-M 1.5 kW & 2 kW, Matched Passive Double-Clad Optical Fiber

LMA-GDF-20/400-HP-M 1.5 kW & 2 kW, Matched Passive Double-Clad Optical Fiber

SKU 1364050
UOM Meter(s)

Coherent Large Mode Area (LMA) passive double clad fibers are ideal for high power fiber lasers and amplifiers used in military, industrial, and medical applications. These fibers feature a 20 micron diameter core and 400 micron diameter clad size with a low NA (0.065) core. They are precision matched to their active counterpart, LMA-YDF-20/400-HP-M, to ensure excellent splice compatability and low loss. As with all Coherent standard Large Mode Area (LMA) fibers, these fibers are proof-tested to 100 kpsi, an industry requirement for long term reliability. They utilize the latest fiber design to ensure excellent preservation of beam quality. The new NuCOATFA-HP high performance coating technology extends the operating life at higher power levels demanded by today’s industrial fiber laser applications.

This product requires a purchase of a minimum quantity of : 19


Price $26.60 USD


Details

Features & Benefits

  • NuCOATFA-HP high performance fluoroacrylate coating — Greater fiber durability at the highest powers and in extreme environmental operating & storage conditions
  • LMA core design — Useful for transmitting high CW powers
  • “Few” moded core design — Easy to maintain single mode LP01 beam through fiber & components
  • All fiber proof tested to > 100 kpsi — Critical for ensuring long term reliability when coiling
Typical Applications
  • High power fiber lasers
  • CW and pulsed amplifiers
  • Military, industrial and medical

Resources

Datasheets
Datasheets

Specs

General

Large Mode Area
Large Mode Area
Fiber Application
Laser Components
Fiber Application
Laser & Amplifier
Product Family
NuMATCH
Product Family
NuMKW
Claddings
Double
Coating Material
Low Index Acrylate
Minimum Operating Wavelength (nanometers)
1015
Maximum Operating Wavelength (nanometers)
1115
Core Diameter (micrometers)
20
Core Numerical Aperture (NA)
0.065
Cladding Attenuation
≤ 15 dB/km at 1095 nm
First Cladding NA
0.46
First Cladding Diameter (micrometers)
395
Coating Diameter (micrometers)
550
Proof Test Level
100 kpsi (0.7 GN/m²)