Connects to CUBE Laser Interface Cable (I/O Interface Control connector), 8 Pin. Offers flying leads to then have connections for input and output, control and signals, from the CUBE Laser.
Length
· 229 mm (9 in.)
Signals Wires Include:
· Manual Mode (Auto-Start), Input
· Ground
· Laser On/Enable, input
· General Fault, output
· Second Emission Lamp (not included), output
· Heat Sink Temperature, output
· Laser Output Power (2 Volts = 100%), output
· Laser Ready (5 Volts = laser ready), output
The CUBE I/O Interface Cable connects to the # 1072166 CUBE Interface Cable (sold separately)